header image

Welcome to ZOZEN

ZOZEN is one of the best modern boiler manufacturers in China, our products include steam boilers, hot water boilers and thermal oil heaters. ZOZEN boiler is located in Wuxi, covers 150 thousand square meters of production area, equipped with first-class production equipment, passed the ISO9001:2000 international quality system certification. The company gained the " S " and " U " steel seal from ASME of US.

Customer service

If you run into any problems with the boiler, please contact us directly by email or fill out the online service request. We will do our best to resolve any problems you might have within 24 hours.

In case of special condition, ZOZEN will forward your request to one of its partnered sales representatives depending on the country and state. The local maintenance personnel will arrive at the customer site as soon as possible.


Total dissolved solids - Wikiped

2019-9-25 · Total dissolved solids (TDS) is a measure of the dissolved combined content of all inorganic and organic substances present in a liquid in molecular, ionized, or micro-granular (colloidal sol) suspended form.Generally, the operational definition is that the solids must be small enough to survive filtration through a filter with 2-micrometer (nominal size, or smaller) pores.

xuyi@zozen.com >

Get A Quote >

Method 9.4 – Boiler, boiler feed water and effluent: tota

2018-5-22 · Boiler water 150 100 1 Boiler feed water 250 200 1 Effluent 120 100 2 5.2 TDS by conductivity (boiler water only) 5.2.1 Calibration of instruments Following the manufacturer's directions, calibrate the pH meter using the 4.00 and 7.00 pH buffer solutions (compensated for a

xuyi@zozen.com >

Get A Quote >

METHODS FOR THE ANALYSIS OF BOILER WAT

2018-5-25 · 15% of TDS (R) 15% of TDS (R) 450 max (0) Boiler Water >10.5 (0) 10-11(R) pH INTRODUCTION At Tongaat we have become aware of the necessity of treating and conditioning our boiler waters, and during the coming 1955 season we are going to carry out a regular procedure for analysing them. This

xuyi@zozen.com >

Get A Quote >

Recommended ABMA & ASME Boiler Water Limits Boile

2015-1-9 · eventually scale, which deposits on the internal surfaces of the boiler. The result: a serious loss of boiler efficiency, and possibly boiler failure. Scale is a buildup of solid material formed on internal boiler surfaces when the concentration of impurities in the boiler water exceeds their solubility limit and precipitation occurs.

xuyi@zozen.com >

Get A Quote >

Boiler water - Wikiped

2019-9-24 · Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam.The term may also be applied to raw water intended for use in boilers, treated boiler feedwater, steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.

xuyi@zozen.com >

Get A Quote >

ideal water tds for steam boiler – Industrial Oil Boiler

Pages – Controlling TDS in the Boiler Water. Controlling TDS in the Boiler Water If a boiler is to supply a given amount of steam, the water blown down must be in addition to this amount. Technical Article Boiler Blowdown – Steam • The maximum acceptable TDS level in the boiler water blowdown water for a Clayton Steam

xuyi@zozen.com >

Get A Quote >

Using Reverse Osmosis for Boiler Pretreatment - Veoli

2015-11-3 · Pretreatment 43 Using Reverse Osmosis for Boiler Pretreatment By James McDonald, PE, CWT and Dave Christophersen, CWT Originally Published: Analyst, Summer 2003 T here are numerous makeup water pretreatment strategies for boiler systems

xuyi@zozen.com >

Get A Quote >

Boiler Water Tests | Viking Water Technology, In

Boiler water chlorides limits are set on the ideas that: The boiler should get good fuel efficiency, and, Based on both makeup and treatment dissolved solids, the total boiler water dissolved solids should not go so high that carryover, scaling and corrosion are a potential problem.

xuyi@zozen.com >

Get A Quote >

What Is The Acceptable Total Dissolved Solids (TDS) L

Total Dissolved Solids, also known as TDS, are inorganic compounds that are found in water such as salts, heavy metals and some traces of organic compounds that are dissolved in water.. Excluding the organic matters that are sometimes naturally present in water and the environment, some of these compounds or substances can be essential in life.

xuyi@zozen.com >

Get A Quote >

Boiler Water Tests | Viking Water Technology, In

Boiler water chlorides limits are set on the ideas that: The boiler should get good fuel efficiency, and, Based on both makeup and treatment dissolved solids, the total boiler water dissolved solids should not go so high that carryover, scaling and corrosion are a potential problem.

xuyi@zozen.com >

Get A Quote >

Steam Purity - Western Regional Boiler Association Ho

Steam Purity versus Steam Quality •Steam purity is the condition of the steam in regards to the purity of the chemistry of the steam expressed as ppb (parts per billion) of TDS, sodium, cation conductivity or silica in the steam •Steam Quality is the condition of the steam in regards to the % of moisture or boiler water carryover in the steam

xuyi@zozen.com >